Chapter 8 of report KD 727 about the VIRYA-12 windmill has been reviewed. The generator armature which had 68 mechanical poles has been changed into an armature with 60 mechanical poles. The advantage of this new armature is that it can be used in combination with the original 6-pole 400/690 V stator winding if the magnets are orientated in the correct way. The magnets can also be orientated such, that a special 12-pole winding can be used. The advantage of a 12-pole winding is that it has the double frequency as for a 6-pole winding.