Report KD 491, originally written in March 2012 but reviewed in October 2018, has been made public and added to the list of public KD-reports. The title of this report is: “Research of the usability of the Solaflux solar pump with a 2.6 mm cam in combination with the VIRYA-3B3 windmill. The Solaflux pump has been tested already in 2003. The use of this pump in combination with the VIRYA-3D windmill is described in the Dutch report KD 114. However, the VIRYA-3D windmill with steel blades is cancelled and in KD 491 it is demonstrated that this pump can also be used in combination with the VIRYA-3B3 windmill with wooden blades.
KD 651 reviewed
Chapter 7.5 of KD 651 has been reviewed. It has been investigated if the vane pump, which is described in KD 661, can be used in combination with the VIRYA-3.6L2 if there is an accelerating gearing with a gear ratio 6.5 : 1 in between the vertical shaft and the pump shaft.
KD 661 added
The new report KD 661 has been added to the menu KD-reports. The title of this report is: “Ideas about a vane pump for low height irrigation directly driven by a 24 V, 0,35 kW, permanent magnet motor frame size 71”. The vane pump described in this report has a high efficiency as the vanes are not pressed against the pump housing. The pump is designed for a maximum static height H = 10 m and has a nominal flow of about 9 m^3 per hour which makes it suitable for irrigation. The pump motor can be powered by a wind turbine or by a solar panel.
KD 539 reviewed
Small mistakes have been corrected in KD 539 in which a fast running vane pump is described. A new chapter 9 has been added. In this chapter it is explained why the housing and the rotor have to be modified to prevent that water in the center of the rotor is blocked if it flows from one side of the cut-out to the other side.
KD 651 added
Report KD 651 has been added to the menu KD-reports. The title of this report is: “Calculations executed for the 4-bladed rotor of the VIRYA-3.6L2 windmill (lambda design = 2, galvanised steel blades) with a Polycord transmission in between the rotor shaft and the vertical shaft to drive a rotating positive displacement pump”. The VIRYA-3.6L2 makes use of the same Polycord transmission as used for the VIRYA-3.6 with lambda design = 3.5 and which is meant to drive a centrifugal pump. Report KD 490 in which many options for water pumping are described, has also been reviewed.
Note about PM-generator FP-640 available
At the bottom of the menu KD-reports you find the new note: “Modification of the PM-generator type FP-640”. This generator is supplied by the organisation WinGenKids. In the note I explain how the original winding can be modified such that the DC voltage is reduced that much that it might be possible to use the generator for a small horizontal axis wind turbine for 12 V or 24 V battery charging.
KD 658 added
Report KD 658 has been added to the menu KD-reports. The tittle of this report is: “Calculations executed for an alternative rotor of the VIRYA-4.2 windmill (lambda design = 6.5, Gö 711 airfoil) used for 24 V battery charging”. The advantage of the alternative VIRYA-4.2 rotor is that it has a higher starting torque coefficient than the original rotor which has a design tip speed ratio of 8. The starting wind speed is therefore lower. The Pel-V curve is better at low wind speeds but worse at high wind speeds. So the alternative rotor is especially meant for regions with low wind speeds.
KD 656 reviewed
A new chapter 6 has been added to report KD 656. In this chapter it is investigated how the rotor and the characteristics change if the 0.5 m long connecting strip which connects both blades is changed by a 0.75 m long connecting strip. It appears that the same blades can be used but that now the connecting strip has to be twisted 4 degrees in stead of 5 degrees. With this bigger rotor, the windmill is called the VIRYA-3.17. The Pel-V curve of the VIRYA-3.17 is better than the one of the VIRYA-2.92.
KD 656 added
Report KD 656 has been added to the menu KD-reports. The title of this report is: “Calculations executed for the 2-bladed rotor of the VIRYA-2.92 windmill (lambda design = 6, stainless steel tapered blades) driving the VIRYA-2.68 PM-generator for 24 V battery charging”.
Wind tunnel measurements of a similar rotor with tapered blades made out of a cylinder have already been performed in 1978. The measurements for a stainless steel rotor with a diameter of 1.8 m and with blades with a sheet thickness of 2 mm are given in report KD 616. This report has inspired me to design a bigger rotor using 3 mm stainless steel sheet for the blades and stainless steel strip size 150 * 6 mm for the connecting strip.
KD 598 reviewed again
A new chapter 7 has been added to report KD 598 about the VIRYA-0.65 floating water turbine. In this chapter it is investigated if the matching in between rotor and generator can be improved by taking a simple 2-bladed rotor with a slightly smaller rotor diameter of 0.625 m in stead of 0.65 m and a design tip speed ratio of 3.5 in stead of 3. The matching of this VIRYA-0.625 for 26 V battery charging and star rectification of the original 230/400 V winding is better than for the VIRYA-0.65. The better matching results in reduction of the cut-in water speed from 0.7 m/s to 0.6 m/s. The starting water speed is increased from 0.37 m/s up to 0.5 m/s but, as it is still lower than the cut-in water speed of 0.6 m/s, this is no problem. The maximum power at V = 2 m/s is 160 W, so the same as for the VIRYA-0.65. The negative effect of the slightly smaller rotor diameter is compensated by the better matching.