Report KD 409 describes the ecliptic safety system with a torsion spring. The spring stiffness has been reduced such that the spring moment for 100 degrees rotation of the vane arm is now a factor 1.5 higher and not a factor 2 higher than at the beginning position. The rated wind speed is increased from 7 m/s up to 8 m/s. These modifications make that the delta-V curve is lying closer to the ideal curve.
review KD 551 and KD 485
Report KD 551 has been extended by a chapter 6 in which the aerodynamic characteristics of rectangular flat plates with aspect ratios of 2 : 1 and 1 : 2 are corrected for wind tunnel blockage. Report KD 485 has been extended by a chapter 4 in which the effect of using an auxiliary vane with an aspect ratio of 2 : 1 in stead of an eccentrically placed rotor is researched.
KD 608 reviewed
Report KD 608 has been reviewed again. Chapter 9 has been added in which the basic measurements are described to determine the wire thickness and the number of turns per coil. The winding is now defined as a 6 V /12 V winding which means that the two coils of one phase have to be connected in series for 12 V battery charging.
KD 608 reviewed, KD 574 cancelled
Report KD 608 has been reviewed such that it now contains the drawings of the rotor and the 8-pole axial flux generator of the VIRYA-1. The rotor calculations are also included in report KD 608. The 8-pole generator is now the standard generator for the VIRYA-1. The 6-pole generator for the VIRYA-1 as described in report KD 574 is cancelled and therefore report KD 574 is cancelled too.
The 8-pole generator of the VIRYA-1 has a synthetic stator sheet and therefore no eddy currents are generated. The sticking torque will therefore be very low and the VIRYA-1 will have a very low starting wind speed and a high maximum efficiency. It is scheduled to build and test a prototype of the VIRYA-1 generator in spring 2016.
Report KD 608 added
The 6-pole, 2-phase axial flux generator of the VIRYA-1 windmill is described in report KD 574. This generator has a steel stator sheet which has as disadvantage that eddy currents are created because of the fluctuating magnetic field. Ideas about an alternative 8-pole, 3-phase axial flux generator are described in the new free public report KD 608. This generator has a synthetic stator sheet and therefore no eddy currents are created. The generator will therefore have a higher maximum efficiency and, as it has no sticking torque, starting of the rotor will be very easily. The VIRYA-1 with this 8-pole generator is expected to function well in areas with low wind speeds. A prototype of the generator has not yet been built.
Report KD 607 and manual VIRYA-2.2 added
The 8-pole, 3-phase axial flux PM-generator and the 2-bladed rotor of the VIRYA-2.2 windmill are described in the new free public report KD 607. A manual of the VIRYA-2.2 including detailled drawings of the rotor and the generator has been added at the bottom of the menu KD-reports. A folder has been made of the five VIRYA-windmills for which the manual and the drawings are available for free. These are the windmills VIRYA-1, VIRYA-1.04, VIRYA-1.36, VIRYA-1.66 and VIRYA-2.2. The folder can be found at the menu VIRYA-folders. The specification of the VIRYA-2.2 has been added to the folder “Extended specification VIRYA windmills” which can be found at the top of the menu VIRYA-folders.
KD 596 reviewed
An extra chapter about a winding with a higher filling rate has been added to report KD 596 in which the VIRYA-1.66 is described.
Manual VIRYA-1.66 added
The free manual of the VIRYA-1.66 has been added at the bottom of the menu KD-reports. The 12-pole axial flux generator and the 3-bladed rotor of the VIRYA-1.66 are described in report KD 596. The manual contains only free drawings of the rotor and the generator. For the remaining drawings read chapter 1 of the manual. A specification of the VIRYA-1.66 is given in the folder “Extended specification” at the top of the menu VIRYA-folders. A folder of the VIRYA-1.66 has not yet been made.
Report KD 596 added
Report KD 596: “Ideas about a 12-pole axial flux generator for the VIRYA-1.66 windmill using 12 neodymium magnets size 25.4 * 25.4 * 12.7 mm. Design report of the rotor (lambda design = 4.5, B = 3, stainless steel blades).” has been added to the menu KD-reports. The 12-pole generator described in this report is derived from the 8-pole generator of the VIRYA-1.36 as described in report KD 571. However, in chapter 10 of KD 596, an alternative 2-layers winding is described with which it is possible to get more copper in the stator and therefore to generate more power at the same rotational speed.
Report KD 579 added
Report KD 578, which was already a public KD-report, has been reviewed. Report KD 579: “Extended calculations executed for the grid connected VIRYA-6.5 windmill” had been added. Both reports link together and give all calculations which have been performed up to now for the VIRYA-6.5 windmill.