Chapter 8 of report KD 727 about the VIRYA-12 windmill has been reviewed. The generator armature which had 68 mechanical poles has been changed into an armature with 60 mechanical poles. The advantage of this new armature is that it can be used in combination with the original 6-pole 400/690 V stator winding if the magnets are orientated in the correct way. The magnets can also be orientated such, that a special 12-pole winding can be used. The advantage of a 12-pole winding is that it has the double frequency as for a 6-pole winding.
KD 718 reviewed
Three new chapters 8, 9 and 10 have been added to report KD 718. The title of chapter 8 is: “Ideas about a 30-pole PM-generator using a 6-pole motor frame size 100L”. The advantage of a 6-pole motor is that the armature volume is larger than for a 4-pole motor of the same frame size and so the maximum torque level will be larger too. The title of chapter 9 is: “Ideas about a 20-pole PM-generator using a 4-pole motor frame size 112M”. Use of a larger frame size also results in increase of the maximum torque level. The title of chapter 10 is: “Ideas about a 30-pole PM-generator using a 6-pole motor frame size 160L”. This rather big generator can be used for a 3-bladed windmill rotor with a diameter of maximal 5 m.
KD 580 reviewed
A new chapter 7.4 has been added to report KD 580 about a small 34-pole PM-generator. The title of this chapter is: “Using a 6-pole stamping frame size 90 and an armature with 38 poles”.
KD 738 reviewed
A new chapter 7 has been added to report KD 738 about the VIRYA-6. The title of this chapter is: “Using of a resistance as load for heating”. It appears that switching from star to delta is a good way to make the rotor start at low wind speeds and to generate power at low wind speeds.
KD 377 reviewed
A new chapter 7 has been added to report KD 377 about the pendulum safety system already written in 2008. The title of this new chapter is: “Using a tension spring instead of balancing weights”.
KD 738 added
Report KD 738 has been added to the menu KD-reports. The title of this report is: “Calculations executed for the 3-bladed rotor of the VIRYA-6 windmill (lambda design = 6) with the pendulum safetey system with a torsion spring connected to the generator type TGET620-5KW-200R for grid connection or heat generation”.
KD 713 herzien
Rapport KD 713 werd herzien. De tekst werd in overeenstemming gebracht met de wijzigingen die in KD 709 werden aangebracht. In hoofdstuk 7 werd een stukje toegevoegd waarbij het reservoir kleiner is en waarbij vooral de windmolen de energie in de winter levert.
KD 285 reviewed
Report KD 285 about the Gö 711 airfoil has been reviewed. New graphs for Cmh0.25 and Cmh0.23 have been added to figure 9. The choice of the turning point for Cmh0.23 gives a Cmh value which is almost constant for a large alpha range.
KD 709 herzien
Rapport KD 709: “Opwekking van warmte met een windmolen in het buitengebied” werd herzien. De VIRYA-6.5 werd vervangen door de VIRYA-5B3.
Commentaar op Verslag thematafels en hoofdtafel
Onderaan het menu KD-reports werd de volgende notitie toegevoegd. Commentaar op “Verslag thematafels en hoofdtafel” van Hannet Johannes. Deze drie bijeenkomsten over de energietransitie werden georganiseerd door de gemeente Meierijstad. De twee thematafels heb ik bijgewoond.